Dynamic Blood Oxygen Saturation Monitoring based on a New IPPG Detecting Device | Proceedings of the 2021 11th International Conference on Biomedical Engineering and Technology (2024)

research-article

Authors: Jingjing Luo, Jie-Wen Li, Min Wei, Yunjie Li, + 4, Zhengrong Yan, Yang Wang, Yuhao Guo, and Zhongxue Gan (Less)

ICBET '21: Proceedings of the 2021 11th International Conference on Biomedical Engineering and Technology

March 2021

Pages 92 - 99

Published: 20 July 2021 Publication History

  • 1citation
  • 114
  • Downloads

Metrics

Total Citations1Total Downloads114

Last 12 Months26

Last 6 weeks4

  • Get Citation Alerts

    New Citation Alert added!

    This alert has been successfully added and will be sent to:

    You will be notified whenever a record that you have chosen has been cited.

    To manage your alert preferences, click on the button below.

    Manage my Alerts

    New Citation Alert!

    Please log in to your account

  • Get Access

      • Get Access
      • References
      • Media
      • Tables
      • Share

    Abstract

    Background: Nowadays, Cardiovascular disease is a severe threat to human health. It is necessary to monitor the cardiovascular parameters such as blood oxygen saturation reliably and conveniently. Non-contact measurement has been widely studied. However, some inevitable factors limit the use of the platform and even lead to inaccurate estimation. Hence, this study proposed a new method to estimate blood oxygen saturation.

    Methods: This paper introduced a new IPPG device consisting of a dual-wavelength light source system, an enclosed illumination chamber and an RGB camera. In order to get a high-precision SpO2 calculation model, the data obtained and processed from the system are compared to the output of a traditional figure blood volume pulse sensor that was employed on 20 subjects at the same time. The most suitable region of interest (ROI) area was determined based on previous research.

    Findings: The comparison showed that the data from the new IPPG system is consistent and comparable with the traditional pulse oximeter. Compared to other IPPG-based measuring methods, our new IPPG device can remove the motion artifacts caused by body movement well. What's more, the consistency of the environment was maintained and reduce the interference of the external environment during the experiment because of the device.

    References

    [1]

    E.J. Benjamin, M.J. Blaha, S.E. Chiuve, M. Cushman, S.R. Das, R. Deo, Heart Disease and Stroke Statistics-2017 Update: A Report From the American Heart Association, Circulation 135(10) (2017) e146-e603. https://www.ncbi.nlm.nih.gov/ /28122885.

    [2]

    M. Writing Group, D. Mozaffarian, E.J. Benjamin, A.S. Go, D.K. Arnett, M.J. Blaha, Executive Summary: Heart Disease and Stroke Statistics–2016 Update: A Report From the American Heart Association, Circulation 133(4) (2016) 447-54. https://www.ncbi.nlm.nih.gov/ /26811276.

    [3]

    S. Cook, M. Togni, M.C. Schaub, P. Wenaweser, O.M. Hess, High heart rate: a cardiovascular risk factor?, Eur Heart J 27(20) (2006) 2387-93. https://www.ncbi.nlm.nih.gov/ /17000632.

    [4]

    M.M. Scheinman, M.A. Brown, E. Rapaport, Critical Assessment of Use of Central Venous Oxygen Saturation as a Mirror of Mixed Venous Oxygen in Severely Ill Cardiac Patients, Circulation 40(2) (1969) 165-172.

    [5]

    G. Pichler, B. Urlesberger, N. Baik, B. Schwaberger, C. Binder-Heschl, A. Avian, Cerebral Oxygen Saturation to Guide Oxygen Delivery in Preterm Neonates for the Immediate Transition after Birth: A2-Center Randomized Controlled Pilot Feasibility Trial, The Journal of Pediatrics 170 (2016) 73-78.e4.

    [6]

    K.R. Walley, Use of Central Venous Oxygen Saturation to Guide Therapy, American Journal of Respiratory and Critical Care Medicine 184(5) (2011) 514-520.

    [7]

    W. McNicholas, Kent, Mitchell, Hypoxemia in patients with COPD: cause, effects, and disease progression, International Journal of Chronic Obstructive Pulmonary Disease (2011).

    [8]

    S. Takatani, P.W. Cheung, E.A. Ernst, A non-invasive tissue reflectance oximeter, Annals of Biomedical Engineering 8(1) (1980) 1-15.

    [9]

    P.W. McCormick, M. Stewart, M.G. Goetting, G. Balakrishnan, Regional cerebrovascular oxygen saturation measured by optical spectroscopy in humans, Stroke 22(5) (1991) 596-602.

    [10]

    W. Verkruysse, L.O. Svaasand, J.S. Nelson, Remote plethysmographic imaging using ambient light, Optics Express 16(26) (2008).

    [11]

    F.P. Wieringa, F. Mastik, A.F.W.v.d. Steen, Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” Technology, Annals of Biomedical Engineering 33(8) (2005) 1034-1041.

    [12]

    A.A.R. Kamal, J.B. Harness, G. Irving, A.J. Mearns, Skin photoplethysmography — a review, Computer Methods and Programs in Biomedicine 28(4) (1989) 257-269.

    [13]

    J. Allen, Photoplethysmography and its application in clinical physiological measurement, Physiological Measurement 28(3) (2007) R1-R39.

    [14]

    M.-Z. Poh, D.J. McDuff, R.W. Picard, Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam, IEEE Transactions on Biomedical Engineering 58(1) (2011) 7-11.

    [15]

    C.G. Scully, L. Jinseok, J. Meyer, A.M. Gorbach, D. Granquist-Fraser, Y. Mendelson, Physiological Parameter Monitoring from Optical Recordings With a Mobile Phone, IEEE Transactions on Biomedical Engineering 59(2) (2012) 303-306.

    [16]

    W.P. Joyce, K. Walsh, D.B. Gough, T.F. Gorey, J.M. Fitzpatrick, Pulse oximetry: A new non-invasive assessment of peripheral arterial occlusive disease, British Journal of Surgery 77(10) (1990) 1115-1117.

    [17]

    J.E. Sinex, Pulse oximetry: Principles and limitations, The American Journal of Emergency Medicine 17(1) (1999) 59-66.

    [18]

    M.C. Wilkins, Residual bacterial contamination on reusable pulse oximetry sensors, Respir Care 38(11) (1993) 1155-60. https://www.ncbi.nlm.nih.gov/ /10145923.

    [19]

    X.F. Teng, Y.T. Zhang, The effect of contacting force on photoplethysmographic signals, Physiol Meas 25(5) (2004) 1323-35. https://www.ncbi.nlm.nih.gov/ /15535195.

    [20]

    J.A. Pollard, Cardiac arrhythmias and pulse variability: a plethysmographic study, Anaesthesia 25(1) (1970) 63-72. https://www.ncbi.nlm.nih.gov/ /5413231.

    [21]

    H.D. Hummler, A. Engelmann, F. Pohlandt, J. Hogel, A.R. Franz, Accuracy of pulse oximetry readings in an animal model of low perfusion caused by emerging pneumonia and sepsis, Intensive Care Med 30(4) (2004) 709-13. https://www.ncbi.nlm.nih.gov/ /14722632.

    [22]

    N.S. Trivedi, A.F. Ghouri, N.K. Shah, E. Lai, S.J. Barker, Effects of motion, ambient light, and hypoperfusion on pulse oximeter function, J Clin Anesth 9(3) (1997) 179-83. https://www.ncbi.nlm.nih.gov/ /9172022.

    [23]

    U. Bal, Non-contact estimation of heart rate and oxygen saturation using ambient light, Biomedical Optics Express 6(1) (2014).

    [24]

    K.H. Shelley, Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate, Anesthesia & Analgesia 105(On Line Suppl.) (2007) S31-S36.

    [25]

    K. Humphreys, T. Ward, C. Markham, Non-contact simultaneous dual wavelength photoplethysmography: A further step toward non-contact pulse oximetry, Review of Scientific Instruments 78(4) (2007).

    [26]

    K. Humphreys, T. Ward, C. Markham, A CMOS Camera-Based Pulse Oximetry Imaging System, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, 2005, pp. 3494-3497.

    [27]

    Y. Sun, N. Thakor, Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging, IEEE Transactions on Biomedical Engineering 63(3) (2016) 463-477.

    [28]

    Q. Fan, K. Li, Non-contact remote estimation of cardiovascular parameters, Biomedical Signal Processing and Control 40 (2018) 192-203.

    [29]

    L. Kong, Y. Zhao, L. Dong, Y. Jian, X. Jin, B. Li, Non-contact detection of oxygen saturation based on visible light imaging device using ambient light, Optics Express 21(15) (2013).

    [30]

    D. Shao, C. Liu, F. Tsow, Y. Yang, Z. Du, R. Iriya, Non-contact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System, IEEE Transactions on Biomedical Engineering 63(6) (2016) 1091-1098.

    Cited By

    View all

    • Zhou FHu SDu XWan XLu ZWu J(2023)Lidom: A Disease Risk Prediction Model Based on LightGBM Applied to Nursing HomesElectronics10.3390/electronics1204100912:4(1009)Online publication date: 17-Feb-2023

    Recommendations

    • A new fibre optic pulse oximeter probe for monitoring splanchnic organ arterial blood oxygen saturation

      A new, continuous method of monitoring splanchnic organ oxygen saturation (SpO2) would make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischaemia, and, ultimately, death. In an attempt to ...

      Read More

    • Investigation of photoplethysmmographic signals and arterial blood oxygen saturation values (SpO2) during blood pressure cuff-induced hypoperfusion

      BIEN '07: Proceedings of the fifth IASTED International Conference: biomedical engineering

      Photoplethysmography is a non-invasive electro-optical technique widely used in the study and monitoring of the pulsations associated with changes in blood volume in a peripheral vascular bed. Photoplethysmography is used in the estimation of arterial ...

      Read More

    • Detecting Four-Limb Blood Oxygen Saturation and Heart Rate based on Reflex Photoplethysmography

      ICSET 2018: Proceedings of the 2nd International Conference on E-Society, E-Education and E-Technology

      The study purpose is to construct a reflective Oxygen Saturation (SpO2) and Heart Rate (HR) four-limb detective device, improve transmission SpO2 device only to measure finger, toe and earlobe. Using Silicon Labs Si1143, Arduino Nano, self-calibrated ...

      Read More

    Comments

    Information & Contributors

    Information

    Published In

    Dynamic Blood Oxygen Saturation Monitoring based on a New IPPG Detecting Device | Proceedings of the 2021 11th International Conference on Biomedical Engineering and Technology (9)

    ICBET '21: Proceedings of the 2021 11th International Conference on Biomedical Engineering and Technology

    March 2021

    200 pages

    ISBN:9781450387897

    DOI:10.1145/3460238

    Copyright © 2021 ACM.

    Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [emailprotected]

    Publisher

    Association for Computing Machinery

    New York, NY, United States

    Publication History

    Published: 20 July 2021

    Permissions

    Request permissions for this article.

    Check for updates

    Author Tags

    1. Blood oxygen saturation
    2. Cardiovascular disease
    3. Imaging photoplethysmography
    4. Systematic design

    Qualifiers

    • Research-article
    • Research
    • Refereed limited

    Funding Sources

    • Key Area Support Plan of Guangdong Province for Jihua Laboratory
    • Shanghai Municipal Science and Technology Major Project
    • Shanghai Science and Technology and Innovation Action Plan

    Conference

    ICBET '21

    Contributors

    Dynamic Blood Oxygen Saturation Monitoring based on a New IPPG Detecting Device | Proceedings of the 2021 11th International Conference on Biomedical Engineering and Technology (10)

    Other Metrics

    View Article Metrics

    Bibliometrics & Citations

    Bibliometrics

    Article Metrics

    • 1

      Total Citations

      View Citations
    • 114

      Total Downloads

    • Downloads (Last 12 months)26
    • Downloads (Last 6 weeks)4

    Other Metrics

    View Author Metrics

    Citations

    Cited By

    View all

    • Zhou FHu SDu XWan XLu ZWu J(2023)Lidom: A Disease Risk Prediction Model Based on LightGBM Applied to Nursing HomesElectronics10.3390/electronics1204100912:4(1009)Online publication date: 17-Feb-2023

    View Options

    Get Access

    Login options

    Check if you have access through your login credentials or your institution to get full access on this article.

    Sign in

    Full Access

    Get this Publication

    View options

    PDF

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader

    HTML Format

    View this article in HTML Format.

    HTML Format

    Media

    Figures

    Other

    Tables

    Dynamic Blood Oxygen Saturation Monitoring based on a New IPPG Detecting Device | Proceedings of the 2021 11th International Conference on Biomedical Engineering and Technology (2024)

    References

    Top Articles
    Latest Posts
    Article information

    Author: Tuan Roob DDS

    Last Updated:

    Views: 5819

    Rating: 4.1 / 5 (62 voted)

    Reviews: 85% of readers found this page helpful

    Author information

    Name: Tuan Roob DDS

    Birthday: 1999-11-20

    Address: Suite 592 642 Pfannerstill Island, South Keila, LA 74970-3076

    Phone: +9617721773649

    Job: Marketing Producer

    Hobby: Skydiving, Flag Football, Knitting, Running, Lego building, Hunting, Juggling

    Introduction: My name is Tuan Roob DDS, I am a friendly, good, energetic, faithful, fantastic, gentle, enchanting person who loves writing and wants to share my knowledge and understanding with you.